worldcreation.info Manuals Yaskawa A1000 Manual Pdf

YASKAWA A1000 MANUAL PDF

Wednesday, June 26, 2019


YASKAWA ELECTRIC SIEP C 27C YASKAWA AC Drive A Errors on page and Refer to Troubleshooting without Fault Display on page YASKAWA ELECTRIC TOEP C 27D - AC Drive A - Quick Start Guide . Table of Contents. 1 SAFETY INSTRUCTIONS 7 TROUBLESHOOTING. The following manuals are available for A series drives: ◇ General Warnings. MANUAL Yaskawa A worldcreation.info - Ebook download as PDF File .pdf), Text File .txt) or read book online.


Yaskawa A1000 Manual Pdf

Author:MARLENA GASSOWAY
Language:English, Spanish, Portuguese
Country:Bosnia Herzegovina
Genre:Health & Fitness
Pages:328
Published (Last):04.03.2016
ISBN:796-4-20886-320-5
ePub File Size:21.36 MB
PDF File Size:18.66 MB
Distribution:Free* [*Registration Required]
Downloads:50383
Uploaded by: LUANA

Fault Display and Troubleshooting. Refer to specifications published in the Yaskawa manual. A Series AC Drive Technical Manual (SIEPC ). YASKAWA AC Drive-A HHP. High Performance Vector Control Drive. Programming Manual. Troubleshooting. Parameter Details. Parameter List. Mechanical Installation. Electrical Installation. Parameter Details. Troubleshooting. Specifications. Parameter List. Standards Compliance. Start-Up Programming.

Emergency Stop When the drive faults out, the output is shut off.

This, however, does not stop the motor immediately. Some type of mechanical brake may be needed if it is necessary to halt the motor faster than the Fast Stop function is able to. Connect only Acompatible devices.

Yaskawa A

Heat stress generated from repetitive high current can shorten the life span of the IGBTs. Yaskawa recommends lowering the carrier frequency, particularly when audible noise is not a concern.

The user can also choose to reduce the load, increase the acceleration and deceleration times, or switch to a larger drive. Be sure to check the peak current levels when starting and stopping repeatedly during the initial test run, and make adjustments accordingly. The drive should be one frame size larger than the motor.

Installation Enclosure Panels Keep the drive in a clean environment by either selecting an area free of airborne dust, lint, and oil mist, or install the drive in an enclosure panel. Be sure to leave the required space between drives to provide for cooling, and that proper measures are taken so that the ambient temperature remains within allowable limits.

Keep flammable materials away from the drive. If the drive must be used in an area where it is subjected to oil mist and excessive vibration, protective designs are available.

Related titles

Contact Yaskawa or your Yaskawa agent for details. Installation Enclosure Panels Keep the drive in a clean environment by either selecting an area free of airborne dust, lint, and oil mist, or install the drive in an enclosure panel. Be sure to leave the required space between drives to provide for cooling, and that proper measures are taken so that the ambient temperature remains within allowable limits.

Keep flammable materials away from the drive. If the drive must be used in an area where it is subjected to oil mist and excessive vibration, protective designs are available. Contact Yaskawa or your Yaskawa agent for details.

Installation Direction The drive should be installed upright as specified in the manual. For more information on installation, Refer to Mechanical Installation on page Settings Upper Limits The drive is capable of running the motor up to Hz.

Due to the danger of accidentally of operating at high speed, be sure to set the upper limit for the frequency. The default setting for the maximum output frequency is 50 Hz.

For faster acceleration and deceleration, install one of the braking options available or increase the capacity of the drive.

Doing so will destroy the drive. Be sure to perform a final check of all sequence wiring and other connections before turning the power on.

Download Center

Type B according to IEC Use the following formula to calculate the amount of voltage drop: A Table 4. Reverse Run Command for 2Wire Sequence on page Failure to comply may result in death or serious injury. Sets the upper limit for ASR as a percentage of the rated load.

You might also like: AIAG FMEA MANUAL PDF

Digital operator J K K. Notes on using analog inputs as Multi-Speed 1.

Drive cover 2 O. Reverse operation enabled Possible to operate the motor in both forward and reverse directions.

Do not allow unqualified personnel to perform work on the drive.